Dexaplan TM 605 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für Zuhause Dexaplan TM 605 herunter. Dexaplan TM 605 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
T 52
Operating and safety instructions
Introduction
Please read the operating instructions thoroughly and carefully before initial opera-
tion of the product. The instruction manual is part of this product and contains impor-
tant information relating to initial operation and handling. Please always observe all
safety instructions. Before initial operation, please check that all parts are fitted cor-
rectly. If you have any questions or are unsure about handling of the device, please
contact the service office for your country. Please keep these instructions in a safe
place. If you give the device to anyone else, please also pass on all documents sup-
plied with it.
Proper use
The TM 605 pressure mat reacts to active pressure loads (visitors or pets) by way of
the inbuilt sensorlm. The alarm unit indicates pressure loads with an acoustic sig-
nal, either a loud siren or a quiet or loud gong tone. The pressure mat can be laid un-
der a flexible, thin carpet, cloth or doormat and must be protected against moisture.
The alarm unit is connected to the twin-core cable (approx. 940 cm) and can be set
up either free-standing or installed with the aid of the supplied fastening material.
The device is suitable for use in dry rooms and areas protected from moisture. It
should be connected to a 9-volt block battery (not included) for operation. The device
is intended for private use only. Any other use or modification of the device consti-
tutes improper use and poses a serious risk of accident. The manufacturer is not lia-
ble for damage caused by improper use or incorrect operation of the device.
Pack contents
1 pressure mat (including approx. 60 cm cable)
1 alarm unit (including approx. 940 cm cable)
2 fastening screws
2 wall plugs
1 operating instructions
Components
Pressure mat (see Fig. A):
Q
Pressure mat (incl. sensor film)
W
Cable socket
Pressure mat TM 605
A
B
E
P
U
T
Y
O
R
Q
W
I
Alarm unit (see Fig. B):
E
Loudspeaker
R
Fixing holes (two on the reverse side
of the device)
T
Battery compartment
Y
Battery clip
U
Battery compartment cover
I
Cable plug
O
Cable
P
Function switch
Technical data
Sensor: sensor film
Operating voltage: 9 V DC
Power supply: 9-volt block battery (6LR61, alkaline)
(not included)
Power consumption: max. 70 mA
Functions:
0 (Off), (Siren signal),
(Quiet gong),
(Loud gong)
Acoustic signal (volume): approx. 30-second siren (95 ± 5 dB (A))
2 x quiet gong (65 ± 5 dB (A))
2 x loud gong (85 ± 5 dB (A))
Pressure mat:
Exterior material: plastic (PVC)
Dimensions: approx. 4 x 560 x 360 mm (h x l x w)
Weight: approx. 195 g
Temperature range: -15°C to +40°C
Alarm unit:
Housing material: plastic (ABS)
Dimensions: 25 x 104 x 56 mm (h x l x w)
Weight: 70 g (without battery and without cable)
Temperature range: 0°C to +40°C (alarm unit)
Protection class: III
Safety instructions
The following instructions are for your own safety and satisfaction when oper-
ating the TM 605 pressure mat. Please note that non-compliance with these
safety instructions can lead to a serious risk of accident.
Explanation of the symbols and terms used:
Danger ! Failure to observe this instruction endangers life and health.
Caution ! Failure to observe this instruction endangers property.
Tip ! Following this advice will help you to achieve optimal results.
Danger !
Do not leave small children unsupervised with the packaging material.
This poses a danger to life by suffocation!
Do not leave children unsupervised with the device. This poses a danger to
life and risk of injury!
Do not use the device in the presence of sick or disabled people or ani
-
mals! Shock caused by the siren poses a danger to life and risk of injury.
Do not damage any gas, electricity, water or telecommunication lines
when fitting the device! This poses a danger to life and risk of injury and
damage
Do not allow leaky or damaged batteries to come into contact with the
skin or eyes! Use suitable protective gloves and clothing. Corrosive acid
poses a danger to life and a risk of injury!
Never expose the device to fire, heat or to temperatures of over 50° C for
any length of time! This poses a danger to life by explosion.
Do not short-circuit the batteries or recharge them! This poses a danger to
life by explosion!
Make sure that your hearing is not exposed to the loud alarm signal for
any length of time! This can cause serious damage to the hearing.
Make sure that the loud siren is not triggered close to the ears. This can
cause serious damage to the hearing!
Handle the cable with care! Install it so that it cannot get damaged and
does not create a stumbling hazard. Otherwise there is a danger to life and
a risk of injury and fire!
Position the pressure mat and the cover so that they do not create a stum
-
bling hazard! Otherwise there is a danger to life and a risk of injury!
Caution !
Operate the device with a 9-volt block battery (6LR61, alkaline) only!
Make sure that you insert the battery with the correct polarity!
Remove the battery from the device during long periods of non-use!
Only use new batteries and under no circumstances used ones!
Do not cover the alarm unit with any objects. This may reduce the volume
of the acoustic signal on the loudspeaker
E
!
Do not allow the pressure mat to come into contact with moisture. Protect
it from rainwater!
Do not allow the alarm unit to come into contact with moisture!
Protect the pressure mat and the alarm unit from strong magnetic or elec
-
tric fields, and from heavy mechanical strain and vibrations! Use the device
with the supplied original parts only or with parts that are suitable for it.
Check before initial operation that all components are assembled in
accordance with the operating instructions!
Before assembly and initial operation of the device, check that the delivery
is complete and undamaged!
The device must only be repaired by authorized and skilled specialists!
Otherwise there is a risk of damage resulting from improper use and loss
of the warranty.
When positioning the pressure mat, make sure that:
- there are no pointed or sharp-edged objects underneath it.
- the surface on which it is laid is even and smooth.
- it is covered by a thin, flexible carpet, a cloth or a doormat to conceal
it from view.
Use the alarm unit at temperatures of 0°C to + 40°C and the pressure mat
at temperatures of -15°C to +40°C! Higher or lower temperatures may
adversely affect operation.
Initial operation
Tip ! The pressure mat reacts sensitively and quickly to pressure loads.
You can use the pressure mat to indicate the presence of welcome visitors (e.g. fam
-
ily or pets) or of unwanted visitors (e.g. intruders) with an acoustic signal. There is a
choice of a quiet or loud gong tone or an approx. 30-second long siren signal.
Preparation and material required:
The stated materials are not included. The information provided here is non-
binding and intended as a guide. The quality of the material depends on indi
-
vidual local requirements.
You will need:
- A 9-volt block battery (6LR61, alkaline) for the power supply (not included).
- A pen to mark the installation points.
- A hammer drill with bit to make the holes for mounting the device on a
wall with the two wall plugs or for cable entry (e.g. in a door frame).
- A crosstip screwdriver for installation with the fastening screws.
Power supply
Caution ! Operate the device with a 9-volt block battery (6LR61, alkaline)
only! Make sure that the battery is inserted with the correct polarity. Remove
the battery from the device during long periods of non-use.
Replace old batteries with new batteries only and never with used ones.
Switch the function switch
P
to the position (“0“).
Remove the battery compartment cover
U
completely from the battery
compartment
T
on the alarm unit housing by pushing the battery com
-
partment cover
U
downwards.
Connect a new 9-Volt block battery to the battery clip
Y
.
Push the battery into the battery compartment
T
.
Fit the battery compartment cover
U
back onto the battery compartment
T
.
Position
Position of the pressure mat
Tip ! Do not use a stiff carpet or doormat to cover the pressure mat, since it
reacts to points of pressure. If the floor and/or the underside of the carpet or
doormat is uneven, malfunctions may occur.
Always spread the pressure mat out on a clean and even surface. Remove
any sharp objects, e.g. stones or grit, since these can cause malfunctions
or irreparably damage the pressure mat.
Detecting people
Choose the area in which the pressure mat is to detect the presence of peo-
ple, e.g. in the entrance area or in front of an area you wish to protect.
Spread the pressure mat out completely on the floor/surface and smooth it
out flat and even (see Fig. A).
KOE31_GB.indd 1-4 29.09.2005 18:08:57 Uhr
Cover the full surface of the entry mat with a cloth, carpet or a doormat.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Pressure mat TM 605

T 52Operating and safety instructionsIntroductionPlease read the operating instructions thoroughly and carefully before initial opera-tion of the prod

Seite 2 - Troubleshooting

Detecting pets (dog or cat) Choose the area in which you wish the pressure mat to detect the pres-ence of your cat or dog, e.g. a patio door.  C

Kommentare zu diesen Handbüchern

Keine Kommentare